AHCI RESEARCH GROUP
Publications
Papers published in international journals,
proceedings of conferences, workshops and books.
OUR RESEARCH
Scientific Publications
How to
You can use the tag cloud to select only the papers dealing with specific research topics.
You can expand the Abstract, Links and BibTex record for each paper.
2008
Gallo, Luigi; Pietro, Giuseppe De; Coronato, Antonio; Marra, Ivana
Toward a Natural Interface to Virtual Medical Imaging Environments Proceedings Article
In: AVI '08 Proceedings of the Working Conference on Advanced Visual Interfaces, pp. 429–432, ACM New York, NY, USA, Napoli, Italy, 2008, ISBN: 978-1-60558-141-5.
Abstract | Links | BibTeX | Tags: 3D interaction, Medical Imaging, Virtual Reality, VTK, Wireless
@inproceedings{galloNaturalInterfaceVirtual2008,
title = {Toward a Natural Interface to Virtual Medical Imaging Environments},
author = { Luigi Gallo and Giuseppe De Pietro and Antonio Coronato and Ivana Marra},
doi = {10.1145/1385569.1385651},
isbn = {978-1-60558-141-5},
year = {2008},
date = {2008-05-01},
booktitle = {AVI '08 Proceedings of the Working Conference on Advanced Visual Interfaces},
pages = {429--432},
publisher = {ACM New York, NY, USA},
address = {Napoli, Italy},
abstract = {Immersive Virtual Reality environments are suitable to support activities related to medicine and medical practice. The immersive visualization of information-rich 3D objects, coming from patient scanned data, provides clinicians with a clear perception of depth and shapes. However, to benefit from immersive visualization in medical imaging, where inspection and manipulation of volumetric data are fundamental tasks, medical experts have to be able to act in the virtual environment by exploiting their real life abilities. In order to reach this goal, it is necessary to take into account user skills and needs so as to design and implement usable and accessible human-computer interaction interfaces. In this paper we present a natural interface for a semi-immersive virtual environment. Such interface is based on an off-the-shelf handheld wireless device and a speech recognition component, and provides clinicians with intuitive interaction modes for inspecting volumetric medical data.},
keywords = {3D interaction, Medical Imaging, Virtual Reality, VTK, Wireless},
pubstate = {published},
tppubtype = {inproceedings}
}
Gallo, Luigi; Pietro, Giuseppe De; Coronato, Antonio; Marra, Ivana
Toward a Natural Interface to Virtual Medical Imaging Environments Proceedings Article
In: AVI '08 Proceedings of the working conference on Advanced visual interfaces, pp. 429–432, ACM New York, NY, USA, Napoli, Italy, 2008, ISBN: 978-1-60558-141-5.
Abstract | Links | BibTeX | Tags: 3D interaction, Medical Imaging, Virtual Reality, VTK, Wireless
@inproceedings{gallo_toward_2008,
title = {Toward a Natural Interface to Virtual Medical Imaging Environments},
author = {Luigi Gallo and Giuseppe De Pietro and Antonio Coronato and Ivana Marra},
doi = {10.1145/1385569.1385651},
isbn = {978-1-60558-141-5},
year = {2008},
date = {2008-05-01},
booktitle = {AVI '08 Proceedings of the working conference on Advanced visual interfaces},
pages = {429–432},
publisher = {ACM New York, NY, USA},
address = {Napoli, Italy},
abstract = {Immersive Virtual Reality environments are suitable to support activities related to medicine and medical practice. The immersive visualization of information-rich 3D objects, coming from patient scanned data, provides clinicians with a clear perception of depth and shapes. However, to benefit from immersive visualization in medical imaging, where inspection and manipulation of volumetric data are fundamental tasks, medical experts have to be able to act in the virtual environment by exploiting their real life abilities. In order to reach this goal, it is necessary to take into account user skills and needs so as to design and implement usable and accessible human-computer interaction interfaces. In this paper we present a natural interface for a semi-immersive virtual environment. Such interface is based on an off-the-shelf handheld wireless device and a speech recognition component, and provides clinicians with intuitive interaction modes for inspecting volumetric medical data.},
keywords = {3D interaction, Medical Imaging, Virtual Reality, VTK, Wireless},
pubstate = {published},
tppubtype = {inproceedings}
}
Gallo, Luigi; Pietro, Giuseppe De; Minutolo, Aniello
Realistic vs. Magic Interaction Metaphors in Virtual Environments Unpublished
2008.
Abstract | BibTeX | Tags: Interaction metaphors, Interaction techniques, Natural User Interfaces, Virtual Reality, Wiimote
@unpublished{galloRealisticVsMagic2008,
title = {Realistic vs. Magic Interaction Metaphors in Virtual Environments},
author = { Luigi Gallo and Giuseppe De Pietro and Aniello Minutolo},
year = {2008},
date = {2008-03-01},
address = {Mogliano Veneto, Italy},
abstract = {Virtual Reality (VR) technologies make it possible to reproduce faithfully real life events in computer-generated scenarios. This approach has the potential to simplify the way people solve problems, since they can take advantage of their real life experiences while interacting in synthetic worlds. In order to convey the users' knowledge to the VR context, interaction metaphors are used. They can be either realistic, i.e. based on real world rules, or magic. In this paper we discuss the subject of interaction metaphors and outline the pros and cons of realistic vs. magic approaches. We also present our experience in the development of interaction techniques in a practical scenario, and suggest an approach to design effective 3D interaction metaphors.},
keywords = {Interaction metaphors, Interaction techniques, Natural User Interfaces, Virtual Reality, Wiimote},
pubstate = {published},
tppubtype = {unpublished}
}
Gallo, Luigi; Pietro, Giuseppe De; Marra, Ivana
User-Friendly Inspection of Medical Image Data Volumes in Virtual Environments Proceedings Article
In: CISIS '08: Proceedings of the International Conference on Complex, Intelligent and Software Intensive Systems, pp. 749–754, IEEE Computer Society, Los Alamitos, CA, USA, Polytechnic University of Catalonia, Spain, 2008, ISBN: 0-7695-3109-1.
Abstract | Links | BibTeX | Tags: 3D interaction, Healthcare, Medical Imaging, Virtual Reality, VOI
@inproceedings{galloUserFriendlyInspectionMedical2008,
title = {User-Friendly Inspection of Medical Image Data Volumes in Virtual Environments},
author = { Luigi Gallo and Giuseppe De Pietro and Ivana Marra},
doi = {10.1109/CISIS.2008.33},
isbn = {0-7695-3109-1},
year = {2008},
date = {2008-03-01},
booktitle = {CISIS '08: Proceedings of the International Conference on Complex, Intelligent and Software Intensive Systems},
pages = {749--754},
publisher = {IEEE Computer Society, Los Alamitos, CA, USA},
address = {Polytechnic University of Catalonia, Spain},
abstract = {In many fields of medicine interactive virtual environments can offer enhanced visualization and manipulation of three-dimensional objects, reconstructed from high-quality scans of human organs. Stereoscopic systems provide users with a natural depth perception about the spatial nature of the structures of interest; moreover advanced user-friendly interfaces, by allowing a natural and intuitive interaction, can strengthen the feeling of being immersed, so to offer clinicians the possibility to act how they do in the real life. In order to enhance the sense of realism specially in medical computer-assisted education, training and diagnostic fields, it is necessary to have a system in which every action can be executed directly into the 3D world without switching to a 2D visualization mode. In this paper we present new interaction techniques to select and extract a volume-of-interest (VOI) in a semi-immersive interactive environment, by using a user-friendly wireless interface, suitable to implement pointing and manipulation features with 6 DOF.},
keywords = {3D interaction, Healthcare, Medical Imaging, Virtual Reality, VOI},
pubstate = {published},
tppubtype = {inproceedings}
}
Gallo, Luigi; Pietro, Giuseppe De; Marra, Ivana
User-Friendly Inspection of Medical Image Data Volumes in Virtual Environments Proceedings Article
In: CISIS '08: Proceedings of the International Conference on Complex, Intelligent and Software Intensive Systems, pp. 749–754, IEEE Computer Society, Los Alamitos, CA, USA, Polytechnic University of Catalonia, Spain, 2008, ISBN: 0-7695-3109-1.
Abstract | Links | BibTeX | Tags: 3D interaction, Healthcare, Medical Imaging, Virtual Reality, VOI
@inproceedings{gallo_user-friendly_2008,
title = {User-Friendly Inspection of Medical Image Data Volumes in Virtual Environments},
author = {Luigi Gallo and Giuseppe De Pietro and Ivana Marra},
doi = {10.1109/CISIS.2008.33},
isbn = {0-7695-3109-1},
year = {2008},
date = {2008-03-01},
booktitle = {CISIS '08: Proceedings of the International Conference on Complex, Intelligent and Software Intensive Systems},
pages = {749–754},
publisher = {IEEE Computer Society, Los Alamitos, CA, USA},
address = {Polytechnic University of Catalonia, Spain},
abstract = {In many fields of medicine interactive virtual environments can offer enhanced visualization and manipulation of three-dimensional objects, reconstructed from high-quality scans of human organs. Stereoscopic systems provide users with a natural depth perception about the spatial nature of the structures of interest; moreover advanced user-friendly interfaces, by allowing a natural and intuitive interaction, can strengthen the feeling of being immersed, so to offer clinicians the possibility to act how they do in the real life. In order to enhance the sense of realism specially in medical computer-assisted education, training and diagnostic fields, it is necessary to have a system in which every action can be executed directly into the 3D world without switching to a 2D visualization mode. In this paper we present new interaction techniques to select and extract a volume-of-interest (VOI) in a semi-immersive interactive environment, by using a user-friendly wireless interface, suitable to implement pointing and manipulation features with 6 DOF.},
keywords = {3D interaction, Healthcare, Medical Imaging, Virtual Reality, VOI},
pubstate = {published},
tppubtype = {inproceedings}
}
Gallo, Luigi; Pietro, Giuseppe De; Minutolo, Aniello
Realistic vs. Magic Interaction Metaphors in Virtual Environments Unpublished
2008.
Abstract | Links | BibTeX | Tags: Interaction metaphors, Interaction techniques, Natural User Interfaces, Virtual Reality, Wiimote
@unpublished{gallo_realistic_2008,
title = {Realistic vs. Magic Interaction Metaphors in Virtual Environments},
author = {Luigi Gallo and Giuseppe De Pietro and Aniello Minutolo},
url = {http://sesar.dti.unimi.it/mtdai08/},
year = {2008},
date = {2008-03-01},
address = {Mogliano Veneto, Italy},
abstract = {Virtual Reality (VR) technologies make it possible to reproduce faithfully real life events in computer-generated scenarios. This approach has the potential to simplify the way people solve problems, since they can take advantage of their real life experiences while interacting in synthetic worlds. In order to convey the users' knowledge to the VR context, interaction metaphors are used. They can be either realistic, i.e. based on real world rules, or magic. In this paper we discuss the subject of interaction metaphors and outline the pros and cons of realistic vs. magic approaches. We also present our experience in the development of interaction techniques in a practical scenario, and suggest an approach to design effective 3D interaction metaphors.},
keywords = {Interaction metaphors, Interaction techniques, Natural User Interfaces, Virtual Reality, Wiimote},
pubstate = {published},
tppubtype = {unpublished}
}
Gallo, Luigi; Pietro, Giuseppe De; Marra, Ivana
3D Interaction with Volumetric Medical Data: Experiencing the Wiimote Proceedings Article
In: 2008 1st International Conference on Ambient Media and Systems (Ambi-Sys), pp. 1–6, ICST, Quebec City, Quebec, Canada, 2008, ISBN: 978-963-9799-16-5.
Abstract | Links | BibTeX | Tags: 3D interaction, Healthcare, Manipulation, Pointing, Usability, Virtual Reality, Wireless
@inproceedings{gallo3DInteractionVolumetric2008,
title = {3D Interaction with Volumetric Medical Data: Experiencing the Wiimote},
author = { Luigi Gallo and Giuseppe De Pietro and Ivana Marra},
doi = {10.4108/ICST.AMBISYS2008.2880},
isbn = {978-963-9799-16-5},
year = {2008},
date = {2008-02-01},
booktitle = {2008 1st International Conference on Ambient Media and Systems (Ambi-Sys)},
pages = {1--6},
publisher = {ICST},
address = {Quebec City, Quebec, Canada},
abstract = {Three-dimensional virtual environments are becoming more and more important for the inspection of volumetric medical data reconstructed from slices of images coming from Magnetic Resonance Imaging (MRI), Computer Tomography (CT), Positron Emission Tomography (PET) instrumentations. The possibility to visualize and interact with three-dimensional reconstructed organs while being immersed into a virtual environment, provides doctors a very naturalistic way to investigate patient's anatomy. However, most 3D user interfaces for immersive and semiimmersive virtual reality applications lack in usability or make not possible a user-friendly interaction. In this paper we present new flavors of existing 3D interaction techniques specifically designed for interacting with volumetric medical data in a semi-immersive virtual environment by using the Nintendo Wiimote controller as 3D user interface.},
keywords = {3D interaction, Healthcare, Manipulation, Pointing, Usability, Virtual Reality, Wireless},
pubstate = {published},
tppubtype = {inproceedings}
}
Gallo, Luigi; Pietro, Giuseppe De; Marra, Ivana
3D Interaction with Volumetric Medical Data: experiencing the Wiimote Proceedings Article
In: 2008 1st international conference on Ambient Media and Systems (Ambi-Sys), pp. 1–6, ICST, Quebec City, Quebec, Canada, 2008, ISBN: 978-963-9799-16-5.
Abstract | Links | BibTeX | Tags: 3D interaction, Healthcare, Manipulation, Pointing, Usability, Virtual Reality, Wireless
@inproceedings{gallo_3d_2008,
title = {3D Interaction with Volumetric Medical Data: experiencing the Wiimote},
author = {Luigi Gallo and Giuseppe De Pietro and Ivana Marra},
doi = {10.4108/ICST.AMBISYS2008.2880},
isbn = {978-963-9799-16-5},
year = {2008},
date = {2008-02-01},
booktitle = {2008 1st international conference on Ambient Media and Systems (Ambi-Sys)},
pages = {1–6},
publisher = {ICST},
address = {Quebec City, Quebec, Canada},
abstract = {Three-dimensional virtual environments are becoming more and more important for the inspection of volumetric medical data reconstructed from slices of images coming from Magnetic Resonance Imaging (MRI), Computer Tomography (CT), Positron Emission Tomography (PET) instrumentations. The possibility to visualize and interact with three-dimensional reconstructed organs while being immersed into a virtual environment, provides doctors a very naturalistic way to investigate patient's anatomy. However, most 3D user interfaces for immersive and semiimmersive virtual reality applications lack in usability or make not possible a user-friendly interaction. In this paper we present new flavors of existing 3D interaction techniques specifically designed for interacting with volumetric medical data in a semi-immersive virtual environment by using the Nintendo Wiimote controller as 3D user interface.},
keywords = {3D interaction, Healthcare, Manipulation, Pointing, Usability, Virtual Reality, Wireless},
pubstate = {published},
tppubtype = {inproceedings}
}